HT 4010 High temperature thermocouple up to 1300°C

HT 4010 High temperature thermocouple up to 1300°C

HT 4010
true
Protection tube
Construction
Closed-end tube
Insertion length
Customer to specify
Diameter
15x2.0mm standard, other diameters possible
Process connection
Sliding flange model MFA (shown)
true
Materials
Tube material
Customer to specify
A) 500 °C
St 35.8 (1.0305)
B) 700 °C
St 35.8 Enamel coated
C) 1200 °C
SS310 X15CrNiSi 2520 (1.4841)
D) 920 °C
SS316/L - (1.4401/1.4404)
E) 1160 °C
Inconel 600
F) 1200 °C
SS446 X10CrAL24 (1.4762)
G) 1150 °C
Sicromal 11 X18CrNi28 (1.4749)
H) 1300 °C
Kanthal AF
true
Connection head
Material
Aluminium or Stainless Steel
Cable entry
M20x1.5 standard, other threads possible
true
Measuring insert
Type
Mineral or Ceramic insulated
true
Thermocouple
Calibration
K, J, N, R, S or B
For duplex
KK, JJ, NN, RR, SS or BB
Accuracy
According to IEC 60584-1
true
Options
Swing-Cover head
DAN, transmitter direct mounted on measuring insert
High Swing-Cover head
DAN-H, transmitter in cover, insert with ceramic block

Customisation possibilities

You can remark the customisation in your quote

PRODUCTCODE

HT 4010
Calibration

Length "L" in mm

Material