LEX55 Ex ec certified RTD for zone 2 and 22

LEX55 Ex ec certified RTD for zone 2 and 22

LEX55
true
Construction
ATEX exectution
II 3 G Ex ec IIC T6...T1 Gc
ATEX certification
DEKRA 18ATEX0024 X
IECEx execution
Ex ec IIC T6...T1 Gb
IECEx certification
IECEx DEK 17.0046X
Suitable for zone
2 and 22
Ingress protection
IP65 / IEC529
Ambient temp. range
Ambient temp. range -45°C...+80°C, this can be limited depending on the materials applied such as cables, connection heads, junction boxes.
true
Connection Head
Model
DAN-AK (showed), other Ex certified connectionheads possible
Material
Aluminium, Stainless Steel or Plastic
Cable entry
M20x1.5 standard, other threads possible
Measuring insert
Construction
Springloaded and replaceable
Springaction
>10mm standard, >40mm optional
Diameter
6.0mm standard, other diameters possible
Type
Mineral insulated (MgO)
true
Sensor
Execution
Single or Duplex Pt100
Connection
3-wire standard, 4-wire optional
Accuracy
According IEC 60751 Cl. B, A or AA
Measuring range
-20°C...+400°C standard, -220°C...+600°C optional
true
Extension
Type
Nipple - union - nipple standard, other constructions possible
Material
Stainless steel
Style / Connection
1/2"NPT standard, other threads possible
Length
150 mm standard, other lengths possible
true
Notes
The LEX55 is the replacement for the LEX45 Ex nA
This datasheet is purely indicative, build-up of model code may vary from this datasheet

Customisation possibilities

You can remark the customisation in your quote

PRODUCTCODE

LEX55
Sensor (S or D)

Class B, A or AA

Length "U" in mm

Length "K" in mm

Deze site is geregistreerd op wpml.org als een ontwikkelingssite. Schakel over naar een productiesite sleutel om remove this banner.