LEX55 Ex ec gecertificeerd thermokoppel voor zone 2 en 22

LEX55 Ex ec gecertificeerd thermokoppel voor zone 2 en 22

LEX55
true
Construction
ATEX execution
II 3 G Ex ec IIC T6...T1 Gc
ATEX certificate
DEKRA 18ATEX0024 X
IECEx execution
Ex ec IIC T6...T1 Gc
IECEx certificate
IECEx DEK 17.0046X
Suitable for zone
2 en 22
Ingress protection
IP65 / IEC529
Ambient temp. range
-45°C...+80°C, this can be limited depending on the materials applied such as cables, connection heads, junction boxes and transmitters.
true
Connection head
Model
DAN-AK (showed), other Ex certified connectionheads possible
Material
Aluminium, Stainless Steel or Plastic
Cable entry
M20x1.5 standard, other threads possible
true
Measuring insert
Construction
Springloaded and replaceble
Springaction
>10mm standard, >40mm optional
Diameter
6.0mm standard, other diameters possible
Type
Mineral insulated (MgO)
true
Thermocouple
Calibration
K, T, J, E, R, S, B, U, N or L
For duplex
KK, TT, JJ, EE, RR, SS, BB, UU, NN or LL
Accuracy
According to IEC 60584-1
true
Extension
Type
Nipple - union - nipple standard, other constructions possible
Material
Stainless Steel
Style / Connection
1/2" NPT standard, other threads possible
Length
150mm standard, other lengths possible
true
Options
Transmitter 4-20 mA
In-Head transmitter, Ex version. Please select from our standard range or specify your own standard
Range
please specify
true
Datasheet notification
true
The LEX55 is the replacement for the LEX45 Ex nA

Customisation possibilities

You can remark the customisation in your quote

PRODUCTCODE

LEX55
Thermocouple calibration

Colourcode

Diameter "D" in mm

Length "U" in mm

Length "X" in mm