HT 4071 High temperature laboratory thermocouple

HT 4071 High temperature laboratory thermocouple

HT 4071
true
Protection tube
Construction
Gastight ceramic
Insertion length
Customer to specify
Diameter
7.0mm standard, other diameters possible
Material
Ceramic 710 (C799)
Temperature
1400°C maximum
true
Connection head
Material
Aluminium or Stainless steel
Cable entry
M20x1.5 standard, other threads possible
true
Measuring insert
Insulation
Ceramic rod
true
Thermocouple
Calibration
B, R or S
For duplex
BB, RR or SS
Wire size
0.35 or 0.5 mm Customer to specify
Accuracy
According IEC 60584
true
Options
Transmitter 4-20 mA
In-Head transmitter, standard or Ex version. Please select from our standard range or specify your own standard
Swing-Cover head
DAN, transmitter direct mounted on measuring insert
High Swing-Cover head
DAN-H, transmitter in cover, insert with ceramic block

Customisation possibilities

You can remark the customisation in your quote

PRODUCTCODE

HT 4071
Calibration

Length "L" in mm