CA 1012 Industrial thermocouple with integrated transmitter

CA 1012 Industrial thermocouple with integrated transmitter

CA 1012
true
Protection tube
Construction
Closed-end tube
Material
SS 316 - (Wst 1.4401) standard, other materials possible
Diameter
9.0mm standard, other diameters possible
Insertion length
Customer to specify
Proces connection
1/2"BSP or other threads possible
true
Connection head
Material
Cast aluminium, plastic or stainless steel
Cable entry
M20x1.5 cable gland standard, other threads possible
true
Measuring insert
Type
MI 2026
Construction
Repleceable springloaded
Diameter
6.0mm standard, other diameters possible
Length
E = L + 45 mm
Material
SS 316 - (Wst 1.4401)
true
Sensor
Thermocouple type
K, T, J, E, N, U or L
For duplex
KK, TT, JJ, EE, NN, UU of LL
Accuracy
IEC 60584
Range
-200 / +600°C
true
Transmitter
Transmitter 4-20mA
In-Head transmitter, standard or Ex version. Please select from our standard range or specify your own standard
Swing-Cover head
DAN, transmitter direct mounted on measuring insert
High Swing-Cover head
DAN-H, transmitter in cover, insert with ceramic block

Customisation possibilities

You can remark the customisation in your quote

PRODUCTCODE

CA 1012
Insertion length "L" in mm

Diameter "D" in mm

Transmitter type

Range (..to.. °C)

Thermocouple type